Warning: fread(): Length parameter must be greater than 0 in /home/upsbazaar/public_html/af/system/library/cache/file.php on line 32Warning: Cannot modify header information - headers already sent by (output started at /home/upsbazaar/public_html/af/system/framework.php:42) in /home/upsbazaar/public_html/af/catalog/controller/startup/startup.php on line 107Warning: fread(): Length parameter must be greater than 0 in /home/upsbazaar/public_html/af/system/library/cache/file.php on line 32Warning: Cannot modify header information - headers already sent by (output started at /home/upsbazaar/public_html/af/system/framework.php:42) in /home/upsbazaar/public_html/af/catalog/controller/startup/startup.php on line 167Warning: fread(): Length parameter must be greater than 0 in /home/upsbazaar/public_html/af/system/library/cache/file.php on line 32Warning: fread(): Length parameter must be greater than 0 in /home/upsbazaar/public_html/af/system/library/cache/file.php on line 32 UPS SW EB 700 (12V)

+91 797-729-3731
    50.33% OFF
  • UPS SW EB 700 (12V)

UPS SW EB 700 (12V)

  • M.R.P.: $82.05
  • Price: $40.75 In Stock

  • Ex Tax: $40.75

MICROTEK UPS SW EB 700 is a Micro Controller design based, LARGEST SELLING SERIES of Extended Backup External Battery UPS Systems. It comes with many user friendly features. It has Voltage Range Selection Switch and can be operated in Standard Voltage Range from 100V~300V and Narrow Voltage Range from 180V~260V. UPS SW EB Series Models are based on Intelli Pure Sinewave Technology which ensures Noiseless,Safe and Efficient Performance along with Longer Backup.



Technical Specifications 



Input

Input Voltage (Standard range)
100 V ~ 300 V
Input Voltage (Narrow range)
180V ~ 260 V


Output

Output Voltage (Mains Mode)
Same as Input
Output Voltage (UPS Mode)
200V~ 230V ± 10%
Output Waveform (Mains Mode)
Same as Input
Output Waveform (UPS Mode)
Pure Sinewave




Changeover

Switchover from Mains to UPS and UPS to Mains
Automatic
UPS Transfer Time
≤ 15 msec.




Technology

Design 
Micro Controller Based Design with IPS Technology
Battery Charging Current
Constant Charging approx. 10% of the rated Battery Current in AH
UPS Overload / UPS Short-circuit
110% / 300%
Browns on Mains Voltage
100V ± 40V
Efficiency (Battery Mode)
> 80%
Auto Reset Feature
Yes
Input DC Range
10.5 V  ~ 14.2 V
Charging Current (Standard)
10 Amps ± 1 Amps
Charging Current (High)
14 Amps ± 1 Amps


Write a review

Note: HTML is not translated!
    Bad           Good